Support

Accord Installer

Please Log In to view or Download. Please Contact Us for a User Id if necessary

Please Install MS SQL Express before installing Accord. Please install an OPC Server before connecting to PLC.

Here is a useful installation guide for SQL Express: https://www.nobledesktop.com/install-sql-server-express

A list of OPC Servers can be found here: https://www.directindustry.com/industrial-manufacturer/opc-server-software-163451.html

—————————————————————————————————————————————————————————————–

Accord User Guides

ItemDateDocument
Designer – Controller24 March 2025Accord Designer V4.10 User Guide – Controller
Server24 March 2025Accord Server V4.10 User Guide
Designer – HMI17 April 2025Accord Designer V4.10 User Guide – HMI
Process Audit24 March 2025Accord Process Audit V1.12 User Guide
Security Audit24 March 2025Accord Security Audit V1.7 User Guide
Recipe3rd Feb 2025Accord Recipe Manager V1.13 User Guide
Plan24 March 2025Accord Plan V1.16 User Guide R01
HMI Runtime24 March 2025Accord HMI Runtime V1.9 User Guide
Defined Reports24 March 2025Accord Defined Reports V1.8 User Guide
Relay3rd Feb 2025Accord Relay User Guide V1.6

—————————————————————————————————————————————————————————————–

Controller Library

Accord systems are generated by modelling, which is far easier and more transparent than coding. The Model is transferred to the PLC where it is implemented by a Controller Library. Accord is available for Siemens and Schneider PLC’s and will be available for Mitsubishi PLC’s in May 2025. Please contact us to obtain the Controller Library.

ItemDateLink
A TIA 4.0.2.1617 April 2025Please Contact Us
A SCH 4.0.2.1611 April 2025Please Contact Us

—————————————————————————————————————————————————————————————–

Recent Updates

We developed Accord 4 during 2024, providing a facelift and a better user experience while retaining the power and consistency from previous versions. We have continued development and recent improvements include the following

SectionDateNote
PLC DownloadNov 2024Download devices in groups instead of individually
Device InterlocksNov 2024Allow Device Alarms as Interlocks
Model DesignDec 2024Improved Grid and Table features
Server SecurityDec 2024Background Verification with notification for any unexpected system settings changes.
Model DesignDec 2024Added notifications for controller status Healthy or Loss of Comms. Added notifications for items not deployed to controller.
Model DesignDec 2024Warnings for references for an item being removed from a Model
ServerJan 2025Full import of External Tags
PlanJan 2025Addition of Plans controlling other Plans
Model DesignJan 2025Split of Writes to Mathematical and Program Control
HMI DesignFeb 2025Change List controls configuration to use Project Explorer instead of Filters
HMI DesignFeb 2025Improved Visibility Links for HMI and PLC conditions
RecipeFeb 2025Simplified by removal of Step Lists and Step On
RecipeFeb 2025Inclusion of Multiple Recipes in a Report
Model DesignMarch 2025Update of Rewire function
HMI DesignMarch 2025Copy of Colour Manager attributes when copying a device.
ControllerMarch 2025Schneider Controller Library
HMI RuntimeMarch 2025Added Historic Value to the Query Control
ServerApril 2025Capture Device Status before Model download to controller and Restore after the download.